Sensor to prevent
overheating : This is the safety
system that provides stopping the burning operation of the
Hung-wall boiler, in case the temperature of the circuit water is
more than 100°C (and the other system sensors cannot fulfill their
duty). In this way, this system provides damaging the hung wall
boiler.
- Control of the Fire with
Ion Electrode: In case the burner is going out,
the ion electrode, that is permanently in contact with flame upon
the burner, is sending this situation to the electronic card and
is turning off the gas. In this way, is prevented the gas
consumption and gas leakage
- The Automatic By-Pass
System: Our Wall-Hung Boilers are provided with a
by-pass pipe wich is allowing the water to pass only into one way
between all way crane and return group. In this way, even if all
the cranes of the wall-hung boiler are closed, it provides the
water circulation of 350 lt/h and prevents damaging of the
boiler.
- Anti-Pump Seizing System
preventing the pump working without water: This is
the safety system stopping the boiler working and preventing Due
to the pressure sensor that is situated on the circulation pump of
the wall-hung boiler, in case the water pressure on the circuit is
under 0,6 bar.
- Anti-Frost System against
Freezing : During cold weather, in case the water
from the inner circuit of the boiler decreases under 5°C the
burner starts burning and is heating the water till 36°C. In this
way the system prevents cracking of the circulation pump, heat
exchanger and other pieces of the boiler due to the freezing
events.
- Anti-Block System
Preventing the Jamming of the Pump : This is the
system providing the functioning of the pump for 20 seconds, once
every 21 hours, in order to prevent the jamming of the pump, in
case the boiler is not used for a long period.
- A Special Filter on the
Entrance of the Cold Water : Due to the filter
positioned after the ball valve allowing the boiler to receive
water, it provides the possibility to clean the water from foreign
substances.
- Anti-Calc System against
Calcifying : The heating of the central heating
water is achieved by a separate steel plate exchanger. In case the
central heating water going through plate exchanger is over a warm
degree, the is capturing calc. Due to the warmth sensor positioned
here, it provides the heating of the water at the expected degree,
meanwhile is preventing the calcifying of the water.
- Safety Valve
: In case the pressure of the water is exceeding
over 3 bar, this valve is providing the evacuation of the water
surplus from the system by using this valve in order to prevent
the damage of the boiler.
- The Gradual Circulation
Pump : This is a system providing the adjustment
of According to the client/user demand.
- Elektronic Full
Modulation : Due to a special programme
electronical card situaated on the boiler, all the operations
regarding the values are provided by an delectronic
card.
- Electronic Ignition
: Using only one button it provides electronic
ignition and the functioning of the boiler.
- Digital Indicators
Control Panel : It is the digital screen system
which is positioned at the front panel of the wall hung
boiler.
- A Sensible Setting of the
Water of Central System and of Heating : Due to
the sensors, different for hot water and heating system of the
boiler a temperature setting of ±1°C can be done providing also
savings of gas and a better confort.
- Isolation Protection
: Our wall hang boiler are produced from inox
sheet iron using the best tehnology of moulding. The burning room
is very well isolated, having also an extra second isolation. Due
to this second isolation it achieves a 5 % savings and isolation
against noise, providing a better functioning and more confort.
This isolation system is realised from one piece only, being a
high quality system in Europe.
|